Product description
1 Conductor de aluminiu compactizat, clasa 2 conform SR EN 60228
2 Extruded semiconductor screen.
3 Izolatie din polietilena reticulata (XLPE)
4 Ecran semiconductor extrudat (neaderent la izolatie)
5 Water-blocking semiconductor tape.
6 Banda de aluminiu cu copolimer, aderenta la mantaua de PE
7 Manta de PE de culoare rosie
8 Marcaj
Cablurile sunt destinate pentru constructia liniilor electrice de medie tensiune.
Cablurile sunt cu protectie transversala si longitudinala la patrunderea apei.
Cablurile se pot monta in aer, in pamant sau in apa.
Specificatie tehnica ENEL Distributie: GSC001
Rated voltage: Uo/U(Um) =12/20 (24) kV
Maximum allowable temperature on the conductor
– during normal operation: +90 °C
– during short circuit (max. 5 s): 250 °C
Temperatura minima la instalare: -20 °C
Temperatura minima in exploatare: -40 °C
Tensiuni de incercare: 42 kV , 50Hz c.a., 5 min
Partial discharge level: max. 5pC
Minimum radius of curvature: 15 x D
D-diametrul exterior al cablului monopolar
Nota: in cazul unei singure indoiri, de exemplu la intrarea in cofrete, tablouri electrice… este permisa o raza de doua ori mai mica cu conditia ca indoirea sa se faca cu atentie, la temperatura de (10-30) °C sau dupa un sablon.
Pulling strength at screening: max. 30 N/mm² de sectiune conductor
- + Construction
1 Conductor de aluminiu compactizat, clasa 2 conform SR EN 60228
2 Extruded semiconductor screen.
3 Izolatie din polietilena reticulata (XLPE)
4 Ecran semiconductor extrudat (neaderent la izolatie)
5 Water-blocking semiconductor tape.
6 Banda de aluminiu cu copolimer, aderenta la mantaua de PE
7 Manta de PE de culoare rosie
8 Marcaj- + Field of use
Cablurile sunt destinate pentru constructia liniilor electrice de medie tensiune.
Cablurile sunt cu protectie transversala si longitudinala la patrunderea apei.
Cablurile se pot monta in aer, in pamant sau in apa.- + Technical data
Specificatie tehnica ENEL Distributie: GSC001
Rated voltage: Uo/U(Um) =12/20 (24) kV
Maximum allowable temperature on the conductor– during normal operation: +90 °C
– during short circuit (max. 5 s): 250 °CTemperatura minima la instalare: -20 °C
Temperatura minima in exploatare: -40 °C
Tensiuni de incercare: 42 kV , 50Hz c.a., 5 min
Partial discharge level: max. 5pC
Minimum radius of curvature: 15 x D
D-diametrul exterior al cablului monopolarNota: in cazul unei singure indoiri, de exemplu la intrarea in cofrete, tablouri electrice… este permisa o raza de doua ori mai mica cu conditia ca indoirea sa se faca cu atentie, la temperatura de (10-30) °C sau dupa un sablon.
Pulling strength at screening: max. 30 N/mm² de sectiune conductor