• Bistrița, Drumul Cetății street, no. 19, Bistrița-Năsăud county

ACB2XCY

Cabluri electrice monofazate cu conductor de aluminiu
cu izolaţie de polietilenă reticulată şi neutru concentric,
pentru branşamente aeriene de 0,6/1 kV

Product description

1 Conductor de faza din aluminiu unifilar (clasa 1) sau multifilar (clasa 2), compactizat conform SR EN 60228
2 Izolatie de XLPE
3 Conductor de neutru concentric din sarme de aluminiu
4 Separating layer
5 Manta exterioara de PVC de culoare neagra rezistenta la intemperii

Pentru bransamente monofazate (unde se cere prevenirea pierderilor sau furtul de energie electrica).

Product standard: SF 123 IPROEB
Rated voltage: Uo/U (Um) = 0,6/1 (1,2) kV
Minimum temperature of the cable (measured on the sheath):
      la montaj: – 10 °C
      in exploatare: – 35 °C
Maximum allowable temperature on the conductor
      in conditii normale de exploatare: 80 °C ;
      la scurtcircuit (max. 5 s): 130 °C
Nota : izolatia de polietilena reticulata permite o temperatura a conductorului de pana la 90 °C in regim continuu, respectiv de 250 °C la scurtcircuit, dar din considerente de rezistenta mecanica s-a limitat temperatura la 80 °C, respectiv la 130 °C.
Test voltage: 3,5 kV, 50 Hz, 5 min
Minimum radius of curvature: 10 x outer diameter
Comportarea la foc: cablurile rezistă la încercarea la flacara conform SR EN 60332-1-2
    rm – multi-wired round conductor (class 2)
    ru – single-wire round conductor (class 1)

+ Construction

1 Conductor de faza din aluminiu unifilar (clasa 1) sau multifilar (clasa 2), compactizat conform SR EN 60228
2 Izolatie de XLPE
3 Conductor de neutru concentric din sarme de aluminiu
4 Separating layer
5 Manta exterioara de PVC de culoare neagra rezistenta la intemperii

+ Field of use

Pentru bransamente monofazate (unde se cere prevenirea pierderilor sau furtul de energie electrica).

+ Technical data

Product standard: SF 123 IPROEB
Rated voltage: Uo/U (Um) = 0,6/1 (1,2) kV
Minimum temperature of the cable (measured on the sheath):
      la montaj: – 10 °C
      in exploatare: – 35 °C
Maximum allowable temperature on the conductor
      in conditii normale de exploatare: 80 °C ;
      la scurtcircuit (max. 5 s): 130 °C
Nota : izolatia de polietilena reticulata permite o temperatura a conductorului de pana la 90 °C in regim continuu, respectiv de 250 °C la scurtcircuit, dar din considerente de rezistenta mecanica s-a limitat temperatura la 80 °C, respectiv la 130 °C.
Test voltage: 3,5 kV, 50 Hz, 5 min
Minimum radius of curvature: 10 x outer diameter
Comportarea la foc: cablurile rezistă la încercarea la flacara conform SR EN 60332-1-2