LDIV 120 kN 160 k...

LDI 160 kN 210 kN - detalii tehnice

LDI3 160 kN 210 kN

LDI 160 kN 210 kN

LDI 160 kN 210 kN

Lant dublu de intindere pentru 400 kV, cu 2 conductoare pe faza




Zona
SMS(kN)
II / A
160
II
210
III
160
IV
160
 
I (mm) 3414 3434 3516 3642
L (mm) 4764-4924 4786-4946 4866-5026 4992-5152
Tip inele IPS-9-TT IPS-12-TT IPS-4-TT IPS-8-TT
de protectie IPI-2-TT IPI-3-TT IPI-6-TT  IPI-6-TT

 

Poz Denumire Buc Material Caracteristici Tehnice
 
1 Carlig de tip balama  2 Ol-Zn B10/25, 250 kN
2 Piesa de distantare  2 Ol-Zn PDf-25/1, 250 kN
3 Furca ochi dreapta  2 Ol-Zn FODS-16(21), 160(210) kN
4 Inel de protectie superior  2 Ol-Zn IPS
5 Izolator compozit, 400 kV  2 Cauciuc siliconic CI-220-II-120/160-TT
        CI-220-III-120/160-TT
        CI-220-IV-120/160-TT
6 Inel de protectie inferior  2 Ol-Zn IPI
7 Furca ochi rasucita  2 Ol-Zn FORS-16(21), 160(210) kN
8 Jug dublu  1 Ol-Zn Jd 500/400-32, 320 kN
9 Ochi dublu rasucit  2 Ol-Zn ODR-20, 200 kN
10 Intinzator reglabil  2 Ol-Zn IROF-18, 180 kN
11 Clema de tractiune  2 Ol-Zn TPDFc 450/75, 95 % UTS

 

Obs:
 

* Distanta de eclatare k este conforma cu supratensiunile de trasnet si de comutatie stabilite de proiectantul ( beneficiarul ) liniei.

 



.